THE GREATEST GUIDE TO WET PENDULUM SLIP RESISTANCE TEST

The Greatest Guide To Wet Pendulum Slip Resistance Test

The Greatest Guide To Wet Pendulum Slip Resistance Test

Blog Article



ATTAR (Advanced Technology Testing & Research)
44/48 Rocco Dr, Scoresby VIC 3179, Australia
+61 1300 139 155
https://maps.app.goo.gl/RoEp6iupmJCuiUxk6

When it comes to making sure safety in industrial, commercial, and residential areas, slip resistance testing is an important element. At ATTAR (Advanced Technology Testing & Research), we concentrate on floor slip resistance testing, concrete moisture testing, and luminance contrast analysis to assist companies and property owners reduce dangers and adhere to security requirements.

With modern devices such as the pendulum slip test maker and moisture meter for concrete, we supply precise and independent slip testing services across Australia. Our know-how covers ASTM F2170 compliance, R Rating assessments, P Ranking tiles, and more, ensuring your floors satisfy the greatest security benchmarks.

Why Slip Resistance Testing is Essential


Slips and falls are among the leading causes of work environment and public injuries. Appropriate slip testing assists recognize harmful surfaces before accidents occur. Whether you need wet pendulum test assessments or pendulum test for slip resistance, ATTAR delivers accurate outcomes to boost security.

Secret Services Used by ATTAR


1. Floor Slip Resistance Testing

- Pendulum slip test (AS 4663).
- R Score and P Score tiles evaluations.
- Independent slip testing services for compliance.

2. Concrete Moisture Testing

- Slab moisture test utilizing sophisticated moisture meter for concrete.
- ASTM F2170 compliant assessments.
- Concrete slab moisture testing to prevent flooring failures.

3. Luminance Contrast Testing

- Ensures visibility for visually impaired individuals.
- Complies with Australian accessibility requirements.

4. On-Site & Lab Testing

- Slip test machine for accurate on-site evaluations.
- Wet pendulum test for damp surface area slip resistance.

Comprehending Slip Resistance Rankings: R Score vs. P Score


When carrying out slip resistance testing, two key classifications are utilized:.

- R Ranking (Ramp Test - DIN 51130)
Procedures slip resistance under lubricated conditions, typically used in Europe.

- P Rating (Pendulum Test - AS 4586)
Assesses vibrant friction using a pendulum test slip resistance machine, widely embraced in Australia.

ATTAR supplies independent slip testing to identify whether your flooring meets the needed pendulum score tiles standards.

The Importance of Concrete Moisture Testing


Excess moisture in concrete slabs can cause floor covering failures, mold growth, and adhesive degradation. Our concrete moisture testing services include:.

> ASTM F2170 certified in-situ relative humidity testing.
> Moisture meter for concrete assessments.
> Slab moisture test to ensure optimum conditions for floor setups.

By finding moisture problems early, we help prevent pricey repairs and ensure lasting flooring efficiency.

Luminance Contrast for Availability Compliance


Appropriate luminance contrast is crucial for aesthetically impaired individuals to navigate areas securely. ATTAR evaluates:.

> Stair edges.
> Door frames.
> Handrails.
> Tactile indications.

Our assessments ensure compliance with Australian Special needs Standards (AS 1428.1).

Why Select ATTAR for Slip Resistance & Moisture Testing?


> NATA Accredited (where applicable).
> Advanced Testing Devices (pendulum slip test, moisture meters).
> Nationwide Service Protection.
> Fast & Trusted Reporting.

For professional slip resistance testing, floor slip resistance testing, and concrete moisture testing, contact ATTAR (Advanced Technology Testing & Research):.

Address: 44/48 Rocco Dr, Scoresby VIC 3179, Australia.
Phone: +61 1300 139 155.

Common Applications of Slip Resistance Testing


1. Commercial & Retail Spaces

Shopping center, restaurants, and workplaces require safe floor covering to prevent client and employee injuries. Our pendulum slip test makes sure compliance with safety guidelines.

2. Industrial & Warehouse Facilities

High-traffic commercial environments need resilient, slip-resistant floor covering. ATTAR's slip testing services help keep work environment security.

3. Healthcare & Aged Care Facilities

Health centers and assisted living home need to reduce slip threats. Our luminance contrast and slip resistance testing ensure safe movement for patients and personnel.

4. Public Facilities

Footpaths, train stations, and federal government buildings require independent slip testing to fulfill accessibility and security requirements.

How ATTAR Conducts Slip Resistance Testing


Action 1: Surface Area Assessment

We assess floor covering materials here and conditions (dry, wet, or infected).

Action 2: Pendulum Slip Test (AS 4663)

Using a slip test maker, we measure the dynamic coefficient of friction (DCOF).

Action 3: Wet Pendulum Test

Mimics slippery conditions to evaluate real-world slip threats.

Step 4: Reporting & Compliance Certification

Comprehensive reports with R Score or P Ranking tiles categories.

The Science Behind Pendulum Slip Testing


The pendulum test slip resistance approach includes a swinging arm with a rubber slider that mimics a foot's movement. The test procedures:.

- Slip Possible Value (SPV).
- Pendulum score tiles category (P0 to P5).

Greater rankings (P4/P5) indicate better slip resistance.

Moisture Testing for Concrete Floors: Avoiding Failures


Moisture-related floor covering failures can be pricey. ATTAR's concrete slab moisture testing consists of:.

- ASTM F2170 in-situ RH probes.
- Moisture meter for concrete spot checks.
- Slab moisture test data analysis.

Conclusion


ATTAR (Advanced Technology Testing & Research) is Australia's trusted company of slip resistance testing, floor slip resistance testing, concrete moisture testing, and luminance contrast evaluations. With innovative technology like the pendulum slip test and moisture meter for concrete, we provide accurate, independent, and compliant testing services.

Ensure your property satisfies safety standards-- contact ATTAR today:.

44/48 Rocco Dr, Scoresby VIC 3179, Australia.
+61 1300 139 155.

By selecting ATTAR, you buy independent slip testing services, pendulum test slip resistance precision, and long-lasting floor security options. Let us assist you develop more secure, compliant, and moisture-resistant environments.

Report this page